Screw Blowerのメーカーや取扱い企業、製品情報、参考価格、ランキングをまとめています。
イプロスは、 製造業 BtoB における情報を集めた国内最大級の技術データベースサイトです。

Screw Blower - メーカー・企業と業務用製品 | イプロスものづくり

Screw Blowerの製品一覧

1~3 件を表示 / 全 3 件

表示件数

[Case Study] Low-Pressure Wastewater Treatment (Energy-Saving Screw Blower Technology)

Introduction to the background of why the overseas water company "ZS" was selected for numerous awards.

We would like to introduce a case where the Northumbrian Water Company, which has received various awards overseas, implemented Atlas Copco's energy-efficient screw blower. The company originally used four lobe-type blowers for aeration, but due to reliability issues with one unit, they considered next-generation high-efficiency screw blowers that can reduce energy consumption by up to 30% compared to lobe-type blowers. 【Installed Products】 ■ Oil-free screw blower ZS ■ Installed motor output: 18.5–160 kW (25–200 hp) ■ Operating pressure: 0.3–1 bar (e) (4–14.5 psig) ■ Capacity (FAD): 75–1292 L/s (271–4631 m³/h) After the introduction of the "ZS," a 20% improvement rate was confirmed. The company decided to switch all blowers to our equipment. We also have the latest model with inverter functionality, the 'ZS 4 VSD+', and the turbo blower 'ZB series.' Please take a look at our catalog. *For more details, please refer to the catalog or feel free to contact us.

  • others
  • Other water treatment equipment
  • Other conveying machines
  • Screw Blower

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Data on Energy Saving from Changing Aeration Blowers in ActiContact

A detailed explanation of energy-saving measures related to the change of aeration blowers in activated sludge contact systems!

This document introduces the equipment overview and improvement efforts at the Akuchikontakuto (contact oxidation biological tank) of the Chuo Pulp Industry Co., Ltd. Kawauchi Plant. By changing from a roots blower to an inverter-type oil-free screw blower, we were able to reduce noise levels while simultaneously achieving energy savings. The document clearly presents the background leading to the equipment installation, a comparison of equipment specifications, and actual energy savings using diagrams and tables. [Contents] ■ Overview of the Akuchikontakuto at the Kawauchi Plant ■ Background leading to equipment installation ■ Overview of the INV-type screw blower ■ Operational status and issues ■ Confirmation of effects from blower replacement *For more details, please refer to the PDF document or feel free to contact us.